Part Number Hot Search : 
PT2314 MBRS1 SMPD5100 HIP2122 MM5ZB15H 36030 BFG52 CPT20015
Product Description
Full Text Search
 

To Download L1935 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Objective Product Specification
L1935
Low Noise Amplifier 1800-1950 MHz, 35 dB Gain, 0.9dB Noise Figure
FEATURES
* * * * * Extremely low Noise Figure High IIP3 Superior Return Loss 35 dB Power Gain Balanced Input Stage
L1935
APPLICATION * Repeater * Base Station DESCRIPTION
* 1.9 GHz Low Noise Amplifier employing GaAs die Low Noise Amplifier 1800-1950 MHz 35 dB Gain 0.9dB Noise Figure
LIMITING VALUES
Notes: Operating the device above these parameters may cause permanent damage, Case Temperature Tc=25C
SYMBOL
V1 V2 Tstg Topt
PARAMETER
DC supply voltage Storage Temperature Operating Temperature
MIN.
- 30 -5
MAX.
+12 -7 + 100 + 70
UNIT
V V C C
CHARACTERISTICS
Table 1: Test condition: Case Temperature Tc = 25C, V1 = 10V, V2 = -5V
SYMBOL
f I1 I2 Ga S11 S22 P1dB IIP3 NF
PARAMETER
Frequency Supply Current Supply Current Power Gain Input Return Loss Output Return Loss 1dB Compression Point Input 3rd Order Intercept Point Noise Figure
CONDITIONS
MIN.
1800 20 20 24 10 -
TYP.
35 0.9
MAX.
1950 550 20 -
UNIT
MHz mA mA dB dB dB dBm dBm dB
Page 1 of 2
January 2006
Document Revision Level B
Objective Product Specification
L1935
Low Noise Amplifier 1800-1950 MHz, 35 dB Gain, 0.9dB Noise Figure
DEFINITIONS
Data Sheet Status Objective Product Specification Preliminary Product Specification Product Specification Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 60134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification. This data sheet contains target or goal specifications for product development. This data sheet contains preliminary data; supplementary data may be published later. This data sheet contains final product specifications.
Premier Devices reserves the right to make changes without further notice to any products herein. Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose, nor does Premier Devices assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. "Typical" parameters which may be provided in Premier Devices datasheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including "Typicals" must be validated for each customer application by customers technical experts. Premier Devices does not convey any license under its patent rights nor the rights of others. Premier Devices products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the Premier Devices product could create a situation where personal injury or death may occur. Should Buyer purchase or use Premier Devices products for any such unintended or unauthorized application, Buyer shall indemnify and hold Premier Devices and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, and claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Premier Devices was negligent regarding the design or manufacture of the part.
(c) Premier Devices Germany GmbH 2006
How to contact us:
Premier Devices Germany GmbH
Loeffelholzstrasse 20, D-90441 Nuernberg, Germany Phone: +49 (0) 911 9411 233, FAX: +49 (0) 911 9411 198, Email: sales.germany@premierdevices.com, Internet: http://www.premierdevices.de/
Page 2 of 2
January 2006
Document Revision Level B